TitleProduct

Copeland Compressor High Efficiency Commercial Air Cooled Chiller

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Guangdong

  • Validity to:

    Long-term effective

  • Last update:

    2017-07-01 21:27

  • Browse the number:

    104

Send an inquiries

Company Profile

Shenzhen Eurostars Technology Co., Ltd.

By certification [File Integrity]

Contact:Mr. John(Mr.)  

Email:

Telephone:

Phone:

Area:Guangdong

Address:Guangdong

Website: http://eurostarschiller.shop846.com/

Product Details


1.Air cooled scroll chiller application area

Used in hotel, theater, office building and supermarket. 
 
2.Eurostars air cooled scroll type water chiller general introduction
a)Low Noise
b)High Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price
g)CE certificated
 
3.Eurostars air cooled scroll type Water Chiller Features
1).The Chiller cooling capacity ranged from 2.5Kw to 175 Kw.
2). Adopt good quality famous brand EMERSON Copeland compressor,high efficiency, low noise, less wearing and long life
3).With high efficiency evaporator and condenser
4).World famous brand parts: such Danfoss expansion valve, FUJI contactor other brand like PUNP, Schneider.
5).Water chillers have high COP,average COP keep 4.1-5.6
6).Stable quality, long using life. 
7).Can be widely used in different area,such as in commercial AC, Massage center, Hospital, Hotel, School, etc 
8).Strong unit base frame ensured the equipment stable operation 
9).Adopt leading brand SCM controller
11).Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
 
4.Eurostars air cooled scroll type water chiller main parts photos and brand


5.Eurostars air cooled scroll type water chiller protection devices
1)Pressure protection, 
2)Overload protection,
4)Anti-freeze protection, 
5)Delay protection, 
6)Over-temperature protection, 
7)Water flow protection.
 
6.Eurostars air cooled scroll type water cooled chiller technical parameter
Please ask salesman for detailed complete data or visit our website:
www.eurostarschina.com

Model ESSA- 02STS(1) 02STS(2) 02STS 03STS 05ISTS 05STS 08STS 10STS
Rated Cooling 
Capacity
KW 2.76  5.72  9.31  12.54  15.82  18.73  25.08  31.64 
USRT 0.78  1.63  2.65  3.57  4.50  5.33  7.13  9.00 
×1000 
kcal/h
2.37  4.92  8.01  10.78  13.61  16.11  21.57  27.21 
Input Power (KW) 1.2 2.02 3.15 4.17 4.91 5.61 7.84 9.9
Comp. Input Power×Qty. (KW) 0.74*1 1.52*1 2.41*1 3.24*1 3.98*1 4.68*1 3.24*2 3.98*2
Throttle Mode Capillary Tube
Power Supply 1φ-220-240V-50HZ 3φ-380/400/415/440V-50HZ
Safety Protection Pressure,Overload,Anti-freeze,Delay,
Over-temperature,Water Flow Protection
Refrigerant R22
Condenser Ripple Aluminum Fins around Cooper Pipe
Fan Type Axial Type
Power
(KW)
0.09 0.13 0.19 0.38 0.38 0.38 0.46 0.84
Air flow
(CMH)
1500 2800 4000 6500 6800 7500 9300 12000
Evaporator Type Coil in Tank Type
Chilled liquid 
flow(m³/h)
0.47  0.98  1.60  2.16  2.72  3.22  4.31  5.44 
Dia. of water
 inlet/outlet
DN15 DN20 DN25 DN25 DN25 DN25 DN40 DN40
Water pump Head(m) 20 20 20 20 20 20 20 20
Power(kw) 0.37 0.37 0.55 0.55 0.55 0.55 1.1 1.1
Water tank Material Stainless Steel
Volume(liters) 20 40 50 70 70 80 120 200
Running Noise dB(A) 58 59 60 62 62 62 64 65
Total weight (Kg) 75 120 150 180 180 200 230 260


Model ESSA- 12STS 15DTS 20DTS 25DTS 30TTS 35TTS 35TTS(1) 35TTS(2)
Rated Cooling Capacity KW 37.46  49.32  65.60  74.08  98.40  131.20  148.20  185.20 
USRT 10.65  14.02  18.65  21.06  27.98  37.30  42.14  52.66 
×1000
 kcal/h
32.22  42.42  56.42  63.71  84.62  112.83  127.45  159.27 
Input Power (KW) 11.3 15.44 20.08 22.06 30.57 39.51 44.22 55.1
Comp. Input Power×Qty. (KW) 4.68*2 6.07*2 8.09*2 9.08*2 8.09*3 8.09*4 9.08*4 9.08*5
Throttle Mode Expansion Valve
Power Supply 3φ-380/400/415/440V-50HZ
Safety Protection Pressure,Overload,Anti-freeze,Delay,Over-temperature,Water Flow Protection
Refrigerant R22
Condenser Ripple Aluminum Fins around Cooper Pipe
Fan Type Axial Type
Power
(KW)
0.84 1.1 1.7 1.7 2.55 3.4 3.9 4.2
Air flow
(CMH)
13000 16000 20000 24000 29000 40000 48000 60000
Evaporator Type Coil in Tank Type
Chilled liquid
 flow(m³/h)
6.44  8.48  11.28  12.74  16.92  22.57  25.49  31.85 
Dia. of water 
inlet/outlet
DN40 DN50 DN50 DN50 DN65 DN80 DN80 DN80
Water pump Head(m) 20 20 20 20 20 20 20 20
Power(kw) 1.1 2.2 2.2 2.2 3.75 3.75 4.0 5.5
Water tank Material Stainless Steel
Volume(liters) 200 270 350 350 420 500 600 650
Running Noise dB(A) 65 67 68 68 68 68 68 68
Total weight (Kg) 350 650 750 1200 1300 1500 1800 2100

R407C as below:
Model ESSA- 02STN(1) 02STN(2) 02STN 03STN 05ISTN 05STN 08STN 10STN
Rated Cooling Capacity KW 2.59  5.23  9.23  12.02  15.02  17.81  24.04  30.04 
USRT 0.74  1.49  2.62  3.42  4.27  5.06  6.84  8.54 
×1000 kcal/h 2.23  4.50  7.94  10.34  12.92  15.32  20.67  25.83 
Input Power (KW) 1.19  2.01  3.37  4.24  4.92  5.53  8.18  9.92 
Comp. Input Power×Qty. (KW) 0.73*1 1.51*1 2.63*1 3.31*1 3.99*1 4.6*1 3.31*2 3.99*2
Throttle Mode Capillary Tube
Power Supply 1φ-220-240V-50HZ 3φ-380/400/415/440V-50HZ
Safety Protection Pressure,Overload,Anti-freeze,Delay,Over-temperature,Water Flow Protection
Refrigerant R410A R407C
Condenser Ripple Aluminum Fins around Cooper Pipe
Fan Type Axial Type
Power(KW) 0.09 0.13 0.19 0.38 0.38 0.38 0.46 0.84
Air flow(CMH) 1500 2800 4000 6500 6800 7500 9300 12000
Evaporator Type Coil in Tank Type
Chilled liquid flow(m³/h) 0.45  0.90  1.59  2.07  2.58  3.06  4.13  5.17 
Dia. of water inlet/outlet DN15 DN20 DN25 DN25 DN25 DN25 DN40 DN40
Water pump Head(m) 20 20 20 20 20 20 20 20
Power(kw) 0.37 0.37 0.55 0.55 0.55 0.55 1.1 1.1
Water tank Material Stainless Steel
Volume(liters) 20 40 50 70 70 80 120 200

Model ESSA- 12STN 15DTN 20DTN 25DTN 30TTN 35TTN 35TTN(1) 35TTN(2)
Rated Cooling Capacity KW 35.62  49.36  64.38  74.04  96.57  128.76  148.08  185.10 
USRT 10.13  14.03  18.31  21.05  27.46  36.61  42.10  52.63 
×1000
 kcal/h
30.63  42.45  55.37  63.67  83.05  110.73  127.35  159.19 
Input Power (KW) 11.14 15.72 19.9 22.04 30.3 39.15 44.18 55.05
Comp. Input Power×Qty. (KW) 4.6*2 6.21*2 8*2 9.07*2 8*3 8*4 9.07*4 9.07*5
Throttle Mode Expansion Valve
Power Supply 3φ-380/400/415/440V-50HZ
Safety Protection Pressure,Overload,Anti-freeze,Delay,Over-temperature,Water Flow Protection
Refrigerant R407C
Condenser Ripple Aluminum Fins around Cooper Pipe
Fan Type Axial Type
Power
(KW)
0.84 1.1 1.7 1.7 2.55 3.4 3.9 4.2
Air flow
(CMH)
13000 16000 20000 24000 29000 40000 48000 60000
Evaporator Type Coil in Tank Type
Chilled liquid 
flow(m³/h)
6.13  8.49  11.07  12.73  16.61  22.15  25.47  31.84 
Dia. of water
 inlet/outlet
DN40 DN50 DN50 DN50 DN65 DN80 DN80 DN80
Water pump Head(m) 20 20 20 20 20 20 20 20
Power(kw) 1.1 2.2 2.2 2.2 3.75 3.75 4.0 5.5
Water tank Material Stainless Steel
Volume(liters) 200 270 350 350 420 500 600 650
Running Noise dB(A) 65 67 68 68 68 68 68 68

7.Eurostars air cooled scroll water chiller Quotation Remarks
1.Packing: Standard export package
2.Delivery Day: 25 days after deposit is confirmed
3.Delivery term: CIF,FOB or CNF EX-Work are welcomed
4.Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
Or 100% Irrevocable non-transferred LC at sight
5.Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
6.Validity: 20 days
7.Payment currency: USD
 
8.Eurostars water chiller series
-Commercial Water Cooled Chiller
-Scroll type water cooled water chiller
-Screw type water cooled water chiller
-Flooded type water cooled water chiller
 
-Commercial Air Cooled Chiller
-Scroll type air cooled water chiller
-Screw type air cooled water chiller
 
-Industrial Chiller
-Air cooled industrial chiller(with heat recovery)
-Water cooled industrial chiller(with heat recovery)
-Glycol chiller (with heat recovery)
 
9.Eurostars air cooled scroll type water chiller real photos